Specialists in
Instrument
Calibration and Repair
Highest Quality…
Lab is accredited to ISO/IEC 17025 by the
American Association for Laboratory
Accreditation (A2LA).
Fast Service…
Most instruments serviced in
five business days!
Excellent Value…
Extensive test data on a broad
range of measurement parameters
without breaking the bank!
Reliable Support…
Factory-trained
technicians provide free
diagnostic support and
troubleshooting advice.
InnoCal
®
, service provider for Oakton
Instruments, is pleased to offer innovative
solutions to satisfy your calibration and repair needs.
Trust InnoCal to provide the documentation required
to meet ISO, FDA, USDA, EPA, GLPs/GMPs, and other
quality standards. Have equipment tested to ensure
its accuracy or serviced to maintain optimal
performance today!
NIST-Traceable Calibration
Certificates
Order the catalog numbers listed below to have
calibration certificates provided with your new
equipment purchase or schedule this service on
previously purchased instruments by requesting
a return authorization (RA) number.
Our detailed certificates identify the instrument by
model number, serial number,and company name.
“As found/as left”test data, test procedures,
calibration date, and technician number are also
included.
Repair Service
Keep valuable equipment up and running with
scheduled preventive maintenance and repair. Our
experienced Service Technicians are factory trained
on instrumentation theory and operation, and stay
up to date on the latest product modifications.
Thermometry type Certification test points
†
against NIST-traceable standards
Instrument Probe System (meter+probe)
Catalog number Catalog number Catalog number
J thermocouple Four test points at 0, 100, 230, 410°C (32, 212, 446,770°F) WD-17000-10 WD-17001-10 WD-17002-10
K thermocouple Four test points at 0,100, 230, 410°C (32, 212, 446, 770°F) WD-17000-12 WD-17001-12 WD-17002-12
T thermocouple Four test points at –20, 0, 100, 230°C (–4, 32, 446,770°F) WD-17000-02 WD-17001-02 WD-17002-02
E thermocouple Four test points at 0, 100,230, 410°C (32,212, 446,770°F) WD-17000-14 WD-17001-14 WD-17002-14
RTD 0, 100, 165, 230°C (32, 212, 329, 446°F) WD-17000-04 WD-17001-04 WD-17002-04
Thermistor Three test points at 0, 40, 70°C (32, 104, 158°F) WD-17000-06 WD-17001-06 WD-17002-06
Infrared 50, 100, 200, 230°C (122, 212, 392, 446°F) WD-17004-00 WD-17004-10 WD-17004-20
†
If instruments and/or probes cannot achieve the listed temperature, InnoCal will substitute other test points at our discretion.
NIST-Traceable Temperature Certificates
NIST-Traceable Certificates
All Metrology services are
performed in an ISO/IEC 17025
accredited laboratory. Calibration
certificates are NIST-traceable
unless otherwise stated.Accredited certificates
with calculated uncertainty measurements by
test point are also available for many instrument
parameters. Please contact us at 888-4OAKTON
for details.
Temperature Measurement
Technical Information....................................................................2
Thermocouple ......................................................................3 to 10
RTD ....................................................................................11 to 13
Thermistor..........................................................................14 to 16
Scanning ............................................................................20 to 21
Infrared..............................................................................24 to 27
Temperature Control ................................................22 to 23
Humidity Measurement ..........................................17 to 19
Dataloggers ..................................................................28 to 29
Recorders..................................................................................30
Timers ........................................................................................31
Table of Contents
NIST-traceable
Certification test points Catalog number
certificate for:
Humidity instrument
Three humidity test points (30, 60, and 80% RH)
WD-17030-20
and one temperature test point (22 to 25°C)
Recorder, chart
Ten to fourteen test points (depends on range
WD-17100-00
of recorder) volts (AC/DC) and amps (AC/DC)
Recorder, X-Y
Ten to fourteen test points (depends on range
WD-17100-10
of recorder) volts (AC/DC) and amps (AC/DC)
Recorder, Three humidity test points (30, 60, and 80% RH)
WD-17030-20
temperature/humidity and one temperature test point (22 to 25°C)
Recorder, temperature
Use temperature certification catalog
—
numbers from temperature table below
Timer/Stopwatch Test data supplied in average seconds/day WD-17060-00
1
INSTRUMENTS …setting the standard, again and again
®
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682